Have similar features to the desktop-based exam simulator contains actual International Code Council Fire-Inspector-II Practice Test that will help you grasp every topic Compatible with every operating system such as Mac, Linus, iOS, Windows, and Android Works properly on Google chrome, Internet explorer, Microsoft Edge, Opera, etc. Does not require any special plugins to operate creates an exam atmosphere making candidates more confident. Keep track of your progress with self-analysis Points out mistakes at the end of every attempt.
In order to meet the upcoming Fire-Inspector-II exam, we believe you must be anxiously searching for relevant test materials. After all, it may be difficult to pass the exam just on your own, so we're honored you can see this message today because our Fire-Inspector-II Guide quiz can solve your problems. Since inception, our company has devoted itself to studying the proposition outlines of various examinations so as to design materials closely to the contents of these Fire-Inspector-II exams.
>> Pdf Fire-Inspector-II Files <<
The website pages list the important information about our Fire-Inspector-II real quiz, the exam name and code, the total quantity of the questions and answers, the characteristics and merits of the product, the price, the details and the guarantee of our Fire-Inspector-II Training Materials, the contact methods, the evaluations of the client on our product and the related exams. You can analyze the information the website pages provide carefully before you decide to buy our Fire-Inspector-II exam questions.
NEW QUESTION # 69
Foamed plastics or materials containing foamed plastics used for stage scenery must be approved when tested in accordance with
Answer: D
Explanation:
Foamed plastics or materials containing foamed plastics used for stage scenery must meet strict fire performance requirements to prevent rapid flame spread and fire hazards in assembly occupancies.
The correct fire test standard for these materials is UL 1975 - Standard for Fire Tests for Foamed Plastics Used for Decorative Purposes.
Reference to Fire Inspector Documentation:
1. 2021 International Fire Code (IFC) - Section 807.4.2 (Foamed Plastics for Stage Scenery) IFC 807.4.2 states that foamed plastics used in scenery must be tested and approved per UL 1975 to ensure fire safety.
2. UL 1975 - Standard for Fire Tests for Foamed Plastics Used for Decorative Purposes This standard evaluates the flammability and smoke production of foamed plastics used in decorative applications, including stage scenery.
Detailed Explanation of Answer Choices:
Option A (Correct): UL 1975 is the required test standard for foamed plastics used in stage scenery, ensuring compliance with IFC 807.4.2.
Option B (Incorrect): NFPA 11A deals with foam-water fire suppression systems, not foamed plastics for decorative use.
Option C (Incorrect): CPSC 16CFR relates to consumer product safety regulations but does not address fire safety for foamed plastics on stage scenery.
Option D (Incorrect): ASTM D 1784 is a test for rigid PVC plastics and does not apply to foamed plastics used for stage scenery.
Thus, the correct and verified answer is: A. UL 1975.
NEW QUESTION # 70
In a control area where flammable liquid storage containers are in piles, there shall be a minimum of __ in. of clearance between the top of the storage and the deflector or discharge orifices of a sprinkler system.
Answer: B
Explanation:
Clearance Requirement for Sprinkler Systems Over Flammable Liquid Storage According to International Fire Code (IFC) 2021, Section 5004.6 and NFPA 30: Flammable and Combustible Liquids Code, Section 16.5.1, there must be a minimum of 18 inches of clearance between the top of flammable liquid storage and the deflector or discharge orifices of a sprinkler system.
This ensures unobstructed sprinkler discharge for effective fire suppression.
2. Why 18 Inches is the Correct Answer
The 18-inch clearance allows sprinklers to operate properly, ensuring water distribution is not blocked by stored materials.
NFPA 13 also mandates an 18-inch minimum clearance for standard storage applications with sprinklers.
3. Verification of Other Options
Option B (24 inches) - Incorrect, as the IFC and NFPA specify 18 inches as the minimum requirement.
Option C (30 inches) - Incorrect, as this exceeds the required minimum clearance.
Option D (36 inches) - Incorrect, as the IFC and NFPA do not require this much clearance.
Reference Sources:
International Fire Code (IFC) 2021 - Section 5004.6 (Sprinkler Clearance Over Flammable Liquid Storage) NFPA 30: Flammable and Combustible Liquids Code - Section 16.5.1 NFPA 13: Standard for the Installation of Sprinkler Systems - Minimum Clearance Requirements ICC Fire Inspector II Study Guide (2021) Thus, the correct and verified answer is: A. 18 inches. #
NEW QUESTION # 71
A building under construction which has two stairways shall have a minimum of how many fire extinguishers per floor?
Answer: D
Explanation:
Reference to Fire Extinguisher Requirements in Buildings Under Construction:
NFPA 241 (Standard for Safeguarding Construction, Alteration, and Demolition Operations) Section 13.6.1 and IFC 3309.1 require that:
A minimum of one fire extinguisher per floor is required.
Additional extinguishers are required based on stairwells and floor area.
If a building under construction has two stairways, a minimum of two fire extinguishers must be provided per floor to ensure adequate fire protection coverage.
Fire Safety Considerations for Construction Sites:
Construction sites pose a high fire risk due to temporary electrical systems, combustible materials, and lack of finished fire suppression systems.
Fire extinguishers must be readily available and evenly distributed near exit stairways and pathways for rapid access in case of an emergency.
Clarification of Incorrect Answer Choices:
A: 1 # Incorrect
One extinguisher is the minimum required for floors with only one exit/stairway, but a building with two stairways requires at least two extinguishers.
C: 3 # Incorrect
While more extinguishers can be added for larger areas or high-risk work zones, the minimum requirement remains two for two stairwells.
D: 4 # Incorrect
There is no general requirement for four extinguishers per floor unless dictated by floor size and hazard level.
Conclusion:
The correct and verified answer is B (2 fire extinguishers per floor) based on NFPA 241 and IFC 3309.1, ensuring compliance with fire safety standards for buildings under construction.
NEW QUESTION # 72
A permit is required for storage of high-pile combustible stock in a building when the area of stock exceeds
Answer: A
Explanation:
High-Pile Combustible Storage Permit Requirements
According to the International Fire Code (IFC) 2021, Section 105.6.23, a permit is required for the storage of high-pile combustible stock when the storage area exceeds 2,500 square feet.
2. Definition of High-Pile Storage
High-pile storage is defined as storage of combustible materials on racks or piles exceeding 12 feet in height (or 6 feet for highly combustible materials, such as rubber and plastics).
IFC Table 3206.2 establishes fire protection requirements based on storage height, area, and commodity class.
3. Verification of Other Options
Option A (225 sq. ft.) - Incorrect, as this is far below the 2,500 sq. ft. permit threshold.
Option B (500 sq. ft.) - Incorrect, as the fire code does not require a permit at this level.
Option C (1,000 sq. ft.) - Incorrect, as the IFC specifies 2,500 sq. ft. as the threshold for requiring a permit.
Reference Sources:
International Fire Code (IFC) 2021 - Section 105.6.23 (High-Pile Combustible Storage Permit Requirements) IFC Chapter 32 (High-Piled Storage Regulations) ICC Fire Inspector II Study Guide (2021) Thus, the correct and verified answer is: D. 2,500. #
NEW QUESTION # 73
The maximum travel distance permitted in a one-story, Group F-2 building equipped with automatic sprinklers and automatic smoke and heat roof vents is __ ft.
Answer: B
Explanation:
The maximum travel distance allowed in a one-story Group F-2 (Factory Industrial - Low Hazard) occupancy with automatic sprinklers and automatic smoke and heat vents is regulated by 2021 International Fire Code (IFC) Table 1017.2 - Exit Access Travel Distance.
IFC Table 1017.2 - Maximum Travel Distance:
For a Group F-2 occupancy equipped with an automatic sprinkler system, the maximum allowable exit access travel distance is 400 feet.
However, when automatic smoke and heat vents are installed, the travel distance is limited to 350 feet.
This is because while the sprinklers control fire spread, smoke and heat vents help with smoke control, allowing for extended egress distances but not as much as without them.
Why Other Options Are Incorrect?
A: 250 ft. - Too restrictive; the IFC allows a longer travel distance in this scenario.
B: 300 ft. - Less than the allowed 350 ft.
D: 400 ft. - Only applicable without smoke and heat vents.
NEW QUESTION # 74
......
Due to busy routines, applicants of the 67 - Fire Inspector II Exam (Fire-Inspector-II) exam need real 67 - Fire Inspector II Exam (Fire-Inspector-II) exam questions. When they don't study with updated International Code Council Fire-Inspector-II practice test questions, they fail and lose money. If you want to save your resources, choose updated and actual 67 - Fire Inspector II Exam (Fire-Inspector-II) exam questions of Free4Dump.
Latest Fire-Inspector-II Cram Materials: https://www.free4dump.com/Fire-Inspector-II-braindumps-torrent.html
Fire-Inspector-II pdf exam questions help applicants study for the 67 - Fire Inspector II Exam (Fire-Inspector-II) exam at any time from any location, International Code Council Pdf Fire-Inspector-II Files We hope you can feel that we have cudgeled our brains for providing you the best study materials, Both International Code Council Fire-Inspector-II practice test software is the Fire-Inspector-II practice exam that will give you a real-time Fire-Inspector-II exam preparation environment to solve all 67 - Fire Inspector II Exam Fire-Inspector-II questions, International Code Council Pdf Fire-Inspector-II Files So its status can not be ignored.
A function that has no implementation inherited Fire-Inspector-II or otherwise) is called a pure virtual function, Binding Data to Controls, Fire-Inspector-II PDF exam questions help applicants study for the 67 - Fire Inspector II Exam (Fire-Inspector-II) exam at any time from any location.
We hope you can feel that we have cudgeled our brains for providing you the best study materials, Both International Code Council Fire-Inspector-II practice test software is the Fire-Inspector-II practice exam that will give you a real-time Fire-Inspector-II exam preparation environment to solve all 67 - Fire Inspector II Exam Fire-Inspector-II questions.
So its status can not be ignored, Are you preparing for the Fire-Inspector-II test recently?